Harnessed cables suitable for Bosch Rexroth
readycable® encoder cable suitable for Bosch Rexroth IKS0251, base cable TPE 5xd
- Requirements: For heaviest duty applications
- Outer jacket: TPE
- Overall shield
- Coolant resistant
- Low-temperature-flexible
- Hydrolysis and microbe-resistant
- Halogen-free
- Silicone-free
- UV-resistant
- PVC-free
- Oil resistance:
- Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- CFRIP®
- chainflex® class:7.6.4.1










readycable® encoder cable suitable for Bosch Rexroth IKS0262, base cable TPE 5xd
- Requirements: For heaviest duty applications
- Outer jacket: TPE
- Overall shield
- Coolant resistant
- Low-temperature-flexible
- Hydrolysis and microbe-resistant
- Halogen-free
- Silicone-free
- UV-resistant
- PVC-free
- Oil resistance:
- Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- CFRIP®
- chainflex® class:7.6.4.1










readycable® encoder cable suitable for Bosch Rexroth RKG0020, base cable PVC 15xd
- Requirements: For flexing applications
- Outer jacket: PVC
- Oil resistance: No oil resistance
- Silicone-free
- Flame retardant
- Overall shield
- chainflex® class: 3.1.1.1









readycable® power cable suitable for Bosch Rexroth IKG4020, base cable PVC 15xd
- Requirements: For flexing applications
- Outer jacket: PVC
- Oil resistance: No oil resistance
- Silicone-free
- Flame retardant
- Overall shield
- chainflex® class: 3.1.1.1









readycable® encoder cable suitable for Bosch Rexroth IKS4103, base cable PVC 10xd
- Requirements: For medium duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Silicone-free
- Flame retardant
- chainflex® class: 4.2.2.1










readycable® encoder cable suitable for Bosch Rexroth IKS4103, base cable TPE 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- Halogen-free
- Silicone-free
- Hydrolysis and microbe-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.6.4.1











readycable® encoder cable suitable for Bosch Rexroth IKS0259, base cable TPE 5xd
- Requirements: For heaviest duty applications
- Outer jacket: TPE
- Overall shield
- Coolant resistant
- Low-temperature-flexible
- Hydrolysis and microbe-resistant
- Halogen-free
- Silicone-free
- UV-resistant
- PVC-free
- Oil resistance:
- Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- CFRIP®
- chainflex® class:7.6.4.1










readycable® encoder cable suitable for Bosch Rexroth RKG0020, base cable PVC 10xd
- Requirements: For medium duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Silicone-free
- Flame retardant
- chainflex® class: 4.2.2.1










readycable® encoder cable suitable for Bosch Rexroth RKG0020, base cable TPE 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- Halogen-free
- Silicone-free
- Hydrolysis and microbe-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.6.4.1











readycable® encoder cable suitable for Bosch Rexroth IKS4103, base cable PUR 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® encoder cable suitable for Bosch Rexroth IKS0255, extension cable TPE 5xd
- Requirements: For heaviest duty applications
- Outer jacket: TPE
- Overall shield
- Coolant resistant
- Low-temperature-flexible
- Hydrolysis and microbe-resistant
- Halogen-free
- Silicone-free
- UV-resistant
- PVC-free
- Oil resistance:
- Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- CFRIP®
- chainflex® class:7.6.4.1










readycable® encoder cable suitable for Bosch Rexroth RKG0020, base cable PUR 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® encoder cable suitable for Bosch Rexroth IKS4314, base cable PVC 10xd
- Requirements: For medium duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Silicone-free
- Flame retardant
- chainflex® class: 4.2.2.1










readycable® encoder cable suitable for Bosch Rexroth IKS0315, base cable PVC 10xd
- Requirements: For medium duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Silicone-free
- Flame retardant
- chainflex® class: 4.2.2.1










readycable® encoder cable suitable for Bosch Rexroth IKS4153, extension cable PVC 15xd
- Requirements: For flexing applications
- Outer jacket: PVC
- Oil resistance: No oil resistance
- Silicone-free
- Flame retardant
- Overall shield
- chainflex® class: 3.1.1.1









readycable® encoder cable suitable for Bosch Rexroth IKS4314, base cable TPE 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- Halogen-free
- Silicone-free
- Hydrolysis and microbe-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.6.4.1











readycable® encoder cable suitable for Bosch Rexroth IKS0315, base cable TPE 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- Halogen-free
- Silicone-free
- Hydrolysis and microbe-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.6.4.1











readycable® encoder cable suitable for Bosch Rexroth IKS4314, base cable PUR 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® encoder cable suitable for Bosch Rexroth IKS0315, base cable PUR 7.5xd
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1














